STATION ANTHOUSA (U-5210) |
DESIGN DETAILS |
DESIGN CODE | ASME B31.8 / PED |
DESIGN PRESSURE | 40 barg |
DESIGN TEMPERATURE | -20 ºC / +60 ºC |
MINIMUM / MAXIMUM INLET PRESSURE | 25 barg / 38 barg |
MINIMUM / MAXIMUM OUTLET PRESSURE | 25 barg / 38 barg |
MINIMUM / MAXIMUM INLET TEMPERATURE | +6 ºC / +25 ºC |
MINIMUM / MAXIMUM OUTLET PRESSURE | – |
OPERATING PRESSURE | 25 – 35 barg |
OPERATING TEMPERATURE | – |
DESIGN CAPACITY | 5000 Nm3/h |
METERING SKID DESIGN CAPACITY | 5000 Nm3/h |
|
METERING INFRASTRUCTURE |
METER TYPE | Turbine meter |
NUMBER OF INSTALLED METERING SKIDS | 2 |
NUMBER OF INSTALLED CHROMATOGRAPHS | – |
AUXILIARY EQUIPMENT TOTAL PROBABLE ERROR | P=±0,15%, T=±0,14οC |
ENERGY UNCERTAINTY | ±0,45% |
|
INSTALLATION DETAILS |
METERS CAPACITY | G160 |
METERS DIAMETER | 100 mm |
METERING SKD DIAMETER | 100 mm |
FLOW STRAIGHTENER DESIGN | – |