| PPC KOMOTINI (U-3570) |
| DESIGN DETAILS | |
| DESIGN CODE | ASME VIII Div.1 |
| DESIGN PRESSURE | 70 barg |
| DESIGN TEMPERATURE | -24 ºC / +80 ºC |
| MINIMUM / MAXIMUM INLET PRESSURE | 40 barg / 55 barg |
| MINIMUM / MAXIMUM OUTLET PRESSURE | 28 barg / 35 barg |
| MINIMUM / MAXIMUM INLET TEMPERATURE | +6 ºC / +24 ºC |
| MINIMUM / MAXIMUM OUTLET TEMPERATURE | +3 ºC / +26 ºC |
| OPERATING PRESSURE | – |
| OPERATING TEMPERATURE | – |
| DESIGN CAPACITY | 108000 Nm3/h |
| METERING SKID DESIGN CAPACITY | 54000 Nm3/h |
| ULTRASONIC METERING SKID DESIGN CAPACITY | 20000 Νm3/h |
| |
| METERING INFRASTRUCTURE |
| METER TYPE | Three (3) Orifice metersTwo (2) Ultrasonic meters |
| NUMBER OF INSTALLED METERING SKIDS | 3+2 |
| NUMBER OF INSTALLED CHROMATOGRAPHS | 2 |
| METERING EQUIPMENT TOTAL PROBABLE ERROR | P=±0,15%, ΔP=±0,15%, T=±0,14οC |
| ENERGY UNCERTAINTY | ±0,65% |
| |
| INSTALLATION DETAILS |
| METERS CAPACITY | – |
| METERS DIAMETER | 115 mm |
| METERING SKID DIAMETER | 200 mm |
| FLOW STRAIGHTENER DESIGN | ISO 5167 Z3573 |