Emergency Call
.
LIVADEIA (U-2710)
DESIGN DETAILS 
DESIGN CODEΕΝ 127106, ΕΝ 1594, ΕΝ 13480,  PED 2014/68 EU
DESIGN PRESSURE80 barg
DESIGN TEMPERATURE-20 ºC / +60 ºC
MINIMUM / MAXIMUM INLET PRESSURE25 barg / 75 barg
MINIMUM / MAXIMUM OUTLET PRESSURE9 barg / 19 barg
INLET TEMPERATURE5 ºC / 25 ºC
MINIMUM OUTLET TEMPERATURE-5 ºC
OPERATING PRESSURE
OPERATING TEMPERATURE
DESIGN CAPACITY5.750 Nm3/h
METERING SKID DESIGN CAPACITY5.750 Nm3/h
  
METERING INFRASTRUCTURE 
METER TYPEΣτροβιλομετρητές (Turbinemeters)
NUMBER OF INSTALLED M/R SKIDS2 (1+1)
NUMBER OF INSTALLED CHROMATOGRAPHS
AUXILIARY EQUIPMENT TOTAL PROBABLE ERRORP=±0,15%, T=±0,14 OC
ENERGY UNCERTAINTY±0,45%
  
INSTALLATION DETAILS 
METERS SIZEG250
METERS DIAMETER80 mm (3”)
M/R SKID DIAMETER80 mm (3”)
FLOW STRAIGHTENER DESIGN