| AGIA TRIADA (U-3020) |
| DESIGN DETAILS |
| DESIGN CODE | ANSI B31.8 |
| DESIGN PRESSURE | 70 barg |
| DESIGN TEMPERATURE | -15 °C / +50 °C |
| MINIMUM / MAXIMUM INLET PRESSURE | 38,4 barg / 66,4 barg |
| MINIMUM / MAXIMUM OUTLET PRESSURE | 37,9 barg / 66,4 barg |
| MINIMUM / MAXIMUM INLET TEMPERATURE | + 3°C / + 19°C |
| MINIMUM / MAXIMUM OUTLET TEMPERATURE | + 3°C / + 19°C |
| OPERATING PRESSURE | – |
| OPERATING TEMPERATURE | – |
| DESIGN CAPACITY | 840000 Nm3/h |
| METERING SKID DESIGN CAPACITY | 420000 Nm3/h |
| |
| METERING INFRASTRUCTURE |
| METER TYPE | Ultrasonic Meter |
| NUMBER OF INSTALLED METERING SKIDS | 3 |
| NUMBER OF INSTALLED CHROMATOGRAPHS | 2 |
| AUXILIARY EQUIPMENT TOTAL PROBABLE ERROR | P=±0,15%, T=±0,14οC |
| ENERGY UNCERTAINTY | ±0,47% |
| |
| INSTALLATION DETAILS |
| METERS CAPACITY | 12000 m3/h |
| METERS DIAMETER | 400 mm |
| METERING SKID DIAMETER | 400 mm |
| FLOW STRAIGHTENER DESIGN | – |