ALEXANDROUPOLIS (U-3630) |
DESIGN DETAILS |
DESIGN CODE | ANSI B31.8 |
DESIGN PRESSURE | 80 barg |
DESIGN TEMPERATURE | – / – |
MINIMUM / MAXIMUM INLET PRESSURE | – / 75 barg |
MINIMUM / MAXIMUM OUTLET PRESSURE | – / – |
MINIMUM / MAXIMUM INLET TEMPERATURE | +5 ºC / +26 ºC |
MINIMUM / MAXIMUM OUTLET TEMPERATURE | – |
OPERATING PRESSURE | – |
OPERATING TEMPERATURE | – |
DESIGN CAPACITY | 28000 Nm3/h |
METERING SKID DESIGN CAPACITY | 28000 Nm3/h |
|
METERING INFRASTRUCTURE |
METER TYPE | Turbine meter |
NUMBER OF INSTALLED METERING SKIDS | 2 |
NUMBER OF INSTALLED CHROMATOGRAPHS | – |
AUXILIARY EQUIPMENT TOTAL PROBABLE ERROR | P=±0,15%, T=±0,14οC |
ENERGY UNCERTAINTY | ±0,65% |
|
INSTALLATION DETAILS |
METERS CAPACITY | G1000 |
METERS DIAMETER | 200 mm |
METERING SKID DIAMETER | 200 mm |
FLOW STRAIGHTENER DESIGN | – |