AdG III (U-2840)
DESIGN DETAILS
DESIGN CODEΕΝ 1594 / ΕΝ 13480
DESIGN PRESSURE80 barg
DESIGN TEMPERATURE-20 ºC / +60 ºC
MINIMUM / MAXIMUM INLET PRESSURE25 barg / 75 barg
MINIMUM / MAXIMUM OUTLET PRESSURE
MINIMUM / MAXIMUM INLET TEMPERATURE+6 ºC / +25 ºC
MINIMUM / MAXIMUM OUTLET TEMPERATURE
OPERATING PRESSURE16,7 barg
OPERATING TEMPERATURE
DESIGN CAPACITY23.500 Nm3/h
METERING SKID DESIGN CAPACITY23.500 Nm3/h
 
METERING INFRASTRUCTURE
METER TYPETurbine meter
NUMBER OF INSTALLED METERING SKIDS2 (1+1)
NUMBER OF INSTALLED CHROMATOGRAPHS
AUXILIARY EQUIPMENT TOTAL PROBABLE ERRORP=±0,15%, T=±0,14OC
ENERGY UNCERTAINTY±0,40%
 
INSTALLATION DETAILS
METERS CAPACITYG1000
METERS DIAMETER150 mm (6”)
METERING SKID DIAMETER150 mm (6”)
FLOW STRAIGHTENER DESIGN